Wire color connections in pigtail - Ultra Horizon
The wires from the pigtail on the Cannon D-9 connector supplied with the Ultra Horizon XL are connected as follows:
Cannon D-9 ConnectorColor
RED Connect to +12VDC
BLACK Connect to GROUND
ORANGE Connect to OAT sensor RED
GREEN Connect to OAT sensor GREEN
WHITE Connect to WARNING LIGHT (connect other pole of warning light to +12VDC). If LED, connect WHITE to cathode. See notes on LED lights for more info on LED use.
Use the terminal block for connection of the RDAC (and rotor RPM if applicable)
Last update: 2006-05-08 19:01
Author: Matt
Print this record